From 1461afbc0c02aee3096981febb2384f8bbee1d2c Mon Sep 17 00:00:00 2001 From: Valerio De Benedetto Date: Mon, 24 Jan 2022 20:16:26 +0100 Subject: [PATCH] README --- README.md | 150 ++++++++++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 150 insertions(+) create mode 100644 README.md diff --git a/README.md b/README.md new file mode 100644 index 0000000..14b30fa --- /dev/null +++ b/README.md @@ -0,0 +1,150 @@ +# MODBUSino - A compact MODBUS RTU/TCP C library for microcontrollers + +MODBUSino is a small C library that implements the Modbus protocol. It is especially useful in resource-constrained +system like microcontrollers. +Its main features are: + +- Compact size: only ~1000 lines of code +- No dynamic memory allocations +- Transports: + - RTU + - TCP +- Roles + - Client + - Server +- Function codes: + - 01 (0x01) Read Coils + - 02 (0x02) Read Discrete Inputs + - 03 (0x03) Read Holding Registers + - 04 (0x04) Read Input Registers + - 05 (0x05) Write Single Coil + - 06 (0x06) Write Single Register + - 15 (0x0F) Write Multiple Coils + - 16 (0x10) Write Multiple registers +- Platform-agnostic + - Requires only C99 and its standard library + - Data transport read/write function are implemented by the user +- Broadcast requests and responses + +## At a glance + +```C +#include "modbusino.h" +#include "my_platform_stuff.h" +#include + +int main(int argc, char* argv[]) { + // Set up the TCP connection + void* conn = my_connect_tcp(argv[1], argv[2]); + if (!conn) { + fprintf(stderr, "Error connecting to server\n"); + return 1; + } + + // my_transport_read_byte, my_transport_write_byte and my_sleep are implemented by the user + mbsn_platform_conf platform_conf; + platform_conf.transport = MBSN_TRANSPORT_TCP; + platform_conf.read_byte = my_transport_read_byte; + platform_conf.write_byte = my_transport_write_byte; + platform_conf.sleep = my_sleep_linux; + platform_conf.arg = conn; // Passing our TCP connection handle to the read/write functions + + // Create the modbus client + mbsn_t mbsn; + mbsn_error err = mbsn_client_create(&mbsn, &platform_conf); + if (err != MBSN_ERROR_NONE) { + fprintf(stderr, "Error creating modbus client\n"); + return 1; + } + + // Set only the response timeout. Byte timeout will be handled by the TCP connection + mbsn_set_read_timeout(&mbsn, 1000); + + // Write 2 holding registers at address 26 + uint16_t w_regs[2] = {123, 124}; + err = mbsn_write_multiple_registers(&mbsn, 26, 2, w_regs); + if (err != MBSN_ERROR_NONE) { + fprintf(stderr, "Error writing register at address 26 - %s", mbsn_strerror(err)); + return 1; + } + + // Read 2 holding registers from address 26 + uint16_t r_regs[2]; + err = mbsn_read_holding_registers(&mbsn, 26, 2, r_regs); + if (err != MBSN_ERROR_NONE) { + fprintf(stderr, "Error reading 2 holding registers at address 26 - %s\n", mbsn_strerror(err)); + return 1; + } + + // Close the TCP connection + my_disconnect(conn); + + return 0; +} +``` + +## Installation + +Just copy `modbusino.c` and `modbusino.h` inside your application codebase. + +## Platform functions + +MODBUSino requires the implementation of 3 platform functions, which are passed as function pointers when creating a +client/server instance. + +### Transport read/write + +```C +int read_byte(uint8_t* b, int32_t, void* arg) +int write_byte(uint8_t b, int32_t, void* arg) +``` + +These are your platform-specific methods that read/write data to/from a serial port or a TCP connection. +Both methods should block until the requested byte is read/written. +If your implementation uses a read/write timeout, and the timeout expires, the methods should return 0. +Their return values should be: + +- `1` in case of success +- `0` if no data is available immediately or after an internal timeout expiration +- `-1` in case of error + +### Sleep + +```C +void sleep(uint32_t milliseconds, void* arg) +``` + +This function should sleep for the specified amount of milliseconds. + +### Platform functions argument + +Platform function can access to arbitrary user data through their `void* arg` argument. The argument is useful, for +example, to pass to read/write function the connection they should operate on. +Its initial value can be set on client/server instance creation and changed any time with `mbsn_set_platform_arg` API +method. + +## Platform endianness + +MODBUSino will attempt to detect the endianness of the platform at build time. If the automatic detection fails, you can +set manually the endianness of the platform by defining either `MBSN_BIG_ENDIAN` or `MBSN_LITTLE_ENDIAN` in your build +flags. + +## Tests and examples + +Tests and examples can be built and run on Linux with CMake: + +```sh +mkdir build && cd build +cmake .. +make +``` + +## Misc + +- To reduce code size, you can define `MBSN_STRERROR_DISABLED` to disable the code that converts `mbsn_error`s to + strings +- Debug prints about received and sent messages can be enabled by defining `MBSN_DEBUG` + +## API reference + +API reference is available in the repository [wiki]()